Worcester Bosch Fault Codes

Display codes and remedies for Worcester Bosch boilers.

Back to fault codes

Display CodeDescriptionRemedyResources
A1Pump has run dry or pump has stalled/seized.Check for water leaks.
Free the pump or replace.
Link
A7Hot water NTC sensor defective.Check hot water NTC sensor and connecting lead for circuit breaks/short circuits.Link
A8Break in communication to TD200 or/and RT10.Check electrical connections.Link
b1Code plug not detected.Insert code plug correctly, test and replace if necessary.Link
C6Fan speed too low.Check fan lead and connector, and fan; replace as necessary.Link
E2CH flow NTC sensor defective.
Check CH flow NTC sensor and connecting lead.Link
E9Safety temp. limiter in CH flow has tripped.Check system pressure, check safety temp. limiters, check pump operation, check fuse on pcb, bleed appli- ance.Link
EAFlame not detected.Is gas cock turned on? Check gas supply pressure, power supply, igniter electrode and lead, ionisation sensing electrode and lead, flue duct and C02 level.Link
F0Internal error.Check electrical connector contacts, programmer inter- face module ignition leads are not loose; replace pcb if necessary.
Link
F7Flame detected even though appliance switched off.Check electrode assembly, dry pcb. Flue clear?Link
FAFlame detected after gas shut off.Check gas valve and wiring to gas valve. Clean conden- sation trap and check electrode assembly. Flue clear?Link
FdReset button pressed by mistake.Press reset button again.Link
XX / -¦¦-Siphon fill modeWait about 15 minutes. If it continues for more than half an hour, call an engineer.Link

Gas work stays with a Gas Safe registered engineer. Some codes only apply to a named range — check the model column.