Lowering your flow temperature is the easiest way to cut your gas use and lower energy bills. It can also help reduce boiler wear and tear over time. Select your system type below, then use the slider to estimate your savings.
A non-condensing boiler cannot be optimised in the same way as a condensing boiler. Any saving from a lower flow temperature is much smaller than on a modern condensing boiler.
What still helps:
Replacing it is the larger step. A condensing boiler is the usual swap. A heat pump can take its place where the radiators and the house are suitable.
If this flow is keeping the house warm in peak winter, a heat pump may suit this system without many changes.
Check heat pump suitabilityThe cylinder is assumed to sit 5°C below the flow, and no hotter than 60°C. The gap can be higher than that.
Public campaigns usually cover combi boilers only, because stored hot water has to stay hot enough.
A load-compensating thermostat, sometimes called a modulating thermostat, talks to the boiler instead of just switching it on and off. As rooms get close to the temperature you have set, it turns the flow temperature down. OpenTherm is one common way of doing this; some boilers use the maker’s own protocol.
This is usually the easier extra option to set up: often just a compatible thermostat swap, with no outdoor sensor or heating curve. Many boiler makers sell their own load-compensating controls that talk to their boilers over the maker’s own connection; these usually only work fully with that maker’s boilers, so check compatibility before you buy. If your boiler does not support OpenTherm, the maker’s own control is often the simplest match; some also offer OpenTherm. It can also be used with weather compensation.
A sensible fixed, lower flow temperature is still a good, simple start. That is what the Boiler Optimiser helps you find. If you rent, check with your landlord before you change any controls. See OpenTherm boilers and controls and Vaillant controls.
Weather compensation goes a step further and is a little more advanced. It uses a sensor fitted on an outside wall to turn the boiler’s flow temperature down as the weather gets milder. It works well when it is fitted and set up properly, but for some homes it can complicate things.
That only works well if the heating curve is set for your home. Many combi boilers never had that sensor fitted, or it is there but not set up.
For most homes a sensible fixed, lower flow temperature is the simpler route. That is what the Boiler Optimiser helps you find. If a compensation sensor is already fitted and working, keep using it. If you rent, check with your landlord before you change any controls or have a sensor fitted.