| S.00 |
|
Heating: No heat de- mand |
Heating has no heat demand. The burner is off. |
Heating mode (all models) |
| S.01 |
|
Heating mode: Fan start- up |
The fan start-up for heating mode is activated. |
Heating mode (all models) |
| S.02 |
|
Heating mode: Pump pre-run |
The pump prerun for heating mode is activated. |
Heating mode (all models) |
| S.03 |
|
Heating mode: Ignition |
The ignition for heating mode is activated. |
Heating mode (all models) |
| S.04 |
|
Heating mode: Burner on |
The burner for heating mode is activated. |
Heating mode (all models) |
| S.05 |
|
Heating mode: Pump/fan overrun |
The pump/fan overrun for heating mode is activated. |
Heating mode (all models) |
| S.06 |
|
Heating mode: Fan over- run |
The fan overrun for heating mode is activated. |
Heating mode (all models) |
| S.07 |
|
Heating mode: Pump overrun |
The pump overrun for heating mode is activated. |
Heating mode (all models) |
| S.08 |
|
Heating mode: Anti-cyc- ling time |
The anti-cycling time for heating mode is activated. |
Heating mode (all models) |
| S.10 |
|
DHW demand |
The domestic hot water demand is activated. |
Domestic hot water mode (ecotec combination boilers only) |
| S.11 |
|
DHW mode: Fan start-up |
The fan start-up for domestic hot water mode is activated. |
Domestic hot water mode (ecotec combination boilers only) |
| S.13 |
|
DHW mode: Ignition |
The ignition for domestic hot water mode is activated. |
Domestic hot water mode (ecotec combination boilers only) |
| S.14 |
|
DHW mode: Burner on |
The burner for domestic hot water mode is activated. |
Domestic hot water mode (ecotec combination boilers only) |
| S.15 |
|
DHW mode: Pump/fan overrun |
The pump/fan overrun for domestic hot water mode is activated. |
Domestic hot water mode (ecotec combination boilers only) |
| S.16 |
|
DHW mode: Fan overrun |
The fan overrun for domestic hot water mode is activated. |
Domestic hot water mode (ecotec combination boilers only) |
| S.17 |
|
DHW mode: Pump over- run |
The pump overrun for domestic hot water mode is activated. |
Domestic hot water mode (ecotec combination boilers only) |
| S.20 |
|
DHW demand |
The domestic hot water demand is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.21 |
|
DHW mode: Fan start-up |
The fan start-up for domestic hot water mode is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.22 |
|
DHW mode: Pump pre- run |
The pump prerun for domestic hot water mode is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.23 |
|
DHW mode: Ignition Burner on |
The ignition for domestic hot water mode is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.24 |
|
DHW mode: |
The burner for domestic hot water mode is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.25 |
|
DHW mode: Pump/fan overrun |
The pump/fan overrun for domestic hot water mode is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.26 |
|
DHW mode: Fan overrun |
The fan overrun for domestic hot water mode is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.27 |
|
DHW mode: Pump over- run |
The pump overrun for domestic hot water mode is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.28 |
|
DHW anti-cycling time |
The anti-cycling time for domestic hot water mode is activated. |
Warm start (ecotec combination boilers only) / Charge hot water cylinder (ecotec systems boilers only) |
| S.30 |
|
No heat demand: Con- troller |
Room thermostat blocks heating mode. |
All boilers |
| S.31 |
|
No heat demand: Sum- mer mode |
Summer mode is activated; there is no heat demand. |
All boilers |
| S.32 |
|
Waiting time deviation: Fan speed |
The waiting period for the fan start-up is activated. |
All boilers |
| S.34 |
|
Heating mode: Frost pro- tection |
The frost protection function for heating mode is activated. |
All boilers |
| S.39 |
|
Contact thermostat triggered |
The surface-mounted thermostat or the condensate pump has triggered. |
All boilers |
| S.40 |
|
Comfort protection act- ive |
The comfort protection mode is activated. |
All boilers |
| S.41 |
|
Water pressure too high |
The system pressure is too high. |
All boilers |
| S.42 |
|
Flue non-return flap closed |
Flue non-return flap return signal blocks burner operation (only in conjunction with the multi-functional module) or condensate pump defective, heat demand is blocked. |
All boilers |
| S.46 |
|
Comfort protection: Min- imum load, loss of flame
|
Comfort protection mode for flame loss at minimum load is activated. |
All boilers |
| S.53 |
|
Waiting time: Water shortage |
The product is within the waiting period of the modulation block/operating block function as a result of a water deficiency (flow/return spread too large). |
All boilers |
| S.54 |
|
Waiting time: Water shortage |
Product is in the waiting period of the operation blocking function as a result of low water pressure (temperature gradient). |
All boilers |
| S.57 |
|
Waiting time: Measuring program |
The product is within the waiting period as a result of the measuring programme.
|
All boilers |
| S.58 |
|
Burner modulation limit- ation |
The burner modulation limitation is activated.
|
All boilers |
| S.61 |
|
Fault: Incorrect gas type |
The coding resistor on the PCB does not match the entered gas group (see also F.92) |
All boilers |
| S.62 |
|
Adjust CO2 |
Set the CO2 content. |
All boilers |
| S.63 |
|
Fault: Check gas route |
A fault message is activated. Check the gas route. |
All boilers |
| S.76 |
|
Service message: Check water pressure |
A service message is activated. Check the water pressure. |
All boilers |
| S.88 |
|
Purging programme is running |
The purge programme is activated. |
All boilers |
| S.92 |
|
Water circulation volume self-test |
The self-test for the water circulation volume is activated. |
All boilers |
| S.93 |
|
Flue gas measurement not possible
|
Flue gas analysis is not currently possible. |
All boilers |
| S.96 |
|
Return temperature sensor self-test |
The self-test for the return temperature sensor is activated. |
All boilers |
| S.97 |
|
Water pressure sensor self-test |
The self-test for the water pressure sensor is activated. |
All boilers |
| S.98
|
|
Flow/return temperature sensor self-test |
The self-test for the flow/return temperature sensor is activated. |
All boilers |
| S.99 |
|
Vaillant self-test |
The Vaillant self-test is activated. |
All boilers |