Vaillant Ecotec Emissions Table

SettingsUnitNatural Gas (H)Propane
CO2 after 5 minutes full (MAX)
load mode with
boiler front casing fitted
Vol.–%7.8 - 10.29.7 - 10.7
CO2 after 5 minutes full (MAX)
load mode with boiler
front casing removed
Vol.–%7.6 - 10.09.5 - 10.5
Set for Wobbe index Ws 1522.5
CO value with full load< 250< 250
CO/CO2< 0.0031< 0.0026

Disclaimer: Information on this website is provided for informational purpose therefore we cannot accept liability for subsequent problems. All repair tasks should be carried out by qualified trades people. We may also receive commission payments when you are taken to external websites and complete purchases from third party sellers, once you leave our site, we cannot be held liable for your purchases.