Code | Parameter / Meaning | Display Values / adjustable value or explanations | Factory setting | Own setting | Article Page / Links | |
---|---|---|---|---|---|---|
D.000 | Heating partial load | Adjustable partial heat load in kW Auto: Product automatically adjusts max. partial load to current system demand | Auto | |||
D.001 | Pump overrun: Heating | 1 to 60 min | 5 min | |||
D.002 | Max. anti-cycl. time: Heating | 2 to 60 min | 20 min | |||
D.003 | Outlet temperature actual value | In °C | Not ad- justable | |||
D.004 | Cylinder temperature actual value | In °C | Not ad- justable | |||
D.005 | Heating target flow temperature | In °C; the maximum value that is set in D.071 and is restricted by means of an eBUS control if such a control is connected | Not ad- justable | |||
D.006 | Outlet temperature target value | 35 to 65 °C | Not ad- justable | |||
D.007 | Comfort mode target value APC target value Cylinder temperature target value | Product with integrated domestic hot water generation, and product with integrated domestic hot water genera- tion and shift-load cylinder 35 to 65 °C Product with heating mode only Frost protection is at 15 °C, then 40 to 70 °C (max. temperature can be adjusted under D.020) | Not ad- justable | |||
D.008 | Controller 3-4 | Room thermostat open (no heat requirement) Room thermostat closed (heat requirement) | Not ad- justable | |||
D.009 | eBUS controller target value | n °C | Not ad- justable | |||
D.010 | Internal pump | On, Off | Not ad- justable | |||
D.011 | External pump | On, Off | Not ad- justable | |||
D.012 | Cyl. charging pump | On, Off | Not ad- justable | |||
D.013 | Circulation pump | On, Off | Not ad- justable | |||
D.014 | Pump speed target value | Target value of internal high-efficiency pump in %. Pos- sible settings: 0 = Auto 1 = 53 2 = 60 3 = 70 4 = 85 5 = 100 | 0 = Auto | |||
D.015 | Pump speed actual value | Actual value for internal high-efficiency pump in % | Not ad- justable | |||
D.016 | Controller 24 V DC: Heating mode | Heating mode off/on | Not ad- justable | |||
D.017 | Control type | Control type: 0 = Flow, 1 = Return Return: Automatic detection function for heat output inactive. Max. possible partial heat load when D.000 is on Auto. | ||||
D.018 | Pump operating mode | 1 = Comfort (continuously operating pump) Internal pump is switched on when the heating flow tem- perature is not at Heating off and the heat requirement is enabled via an external control 3 = Eco (intermittently operating pump) Internal pump is switched on every 25 minutes for 5 minutes once the overrun time has elapsed | 3 = Eco | |||
D.019 | Pump operating mode: 2-stage pump | Setting for two-stage pump operating mode 0: Burner mode stage 2, pump prerun/overrun stage 1 1: Heating mode and pump prerun/overrun stage 1, domestic hot water mode stage 2 2: Automatic heating mode, pump prerun/overrun stage 1, domestic hot water mode stage 2 3: Always stage 2 4: Automatic heating mode, pump prerun/overrun stage 1, domestic hot water mode stage 1 | 2 | |||
D.020 | Max. DHW temperature target value | Adjustment range: 50–70 °C (actoSTOR 65 °C) | 65 °C | |||
D.022 | DHW demand | On, Off | Not ad- justable | |||
D.023 | Heating mode status | Heating on, heating off (summer mode) | Not ad- justable | |||
D.025 | Ext. eBUS signal: Cylinder char- ging | On, Off | Not ad- justable | |||
D.026 | Auxiliary relay | 1 = Circulation pump 2 = External pump 3 = Cylinder charging pump 4 = Extraction hood 5 = External solenoid valve 6 = External fault message 7 = Solar pump (not active) 8 = eBUS remote control (not active) 9 = Anti-legionella pump (not active) 10 = Solar valve (not active) | 2 = External pump | |||
D.027 | Accessory relay 1 | Switching of relay 1 on the VR 40 "2 in 7" multi-func- tional module 1 = Circulation pump 2 = External pump 3 = Cylinder charging pump 4 = Extraction hood 5 = External solenoid valve 6 = External fault message 7 = Solar pump (not active) 8 = eBUS remote control (not active) 9 = Anti-legionella pump (not active) 10 = Solar valve (not active) | 2 = External pump | |||
D.028 | Accessory relay 2 | Switching of relay 2 on the VR 40 "2 in 7" multi-func- tional module 1 = Circulation pump 2 = External pump 3 = Cylinder charging pump 4 = Extraction hood 5 = External solenoid valve 6 = External fault message 7 = Solar pump (not active) 8 = eBUS remote control (not active) 9 = Anti-legionella pump (not active) 10 = Solar valve (not active) | 2 = External pump | |||
D.029 | Water circulation vol. actual value | Actual value in m3/h | Not ad- justable | |||
D.033 | Fan speed target value | In rpm | Not ad- justable | |||
D.034 | Fan speed actual value | In rpm | Not ad- justable | |||
D.035 | 3-way valve position | Heating mode Parallel operation (mid-position) DHW mode | Not ad- justable | |||
D.036 | DHW flow rate | In l/min | Not ad- justable | |||
D.039 | Solar inlet temp. actual value | Actual value in °C | Not ad- justable | |||
D.040 | Flow temperature actual value | Actual value in °C | Not ad- justable | |||
D.041 | Return temperature actual value | Actual value in °C | Not ad- justable | |||
D.044 | Ionisation value actual value | Display field 0 to 1020 > 800 no flame < 400 good flame | Not ad- justable | |||
D.046 | Pump mode | 0 = Relay with disable facility 1 = PWM with disable facility | 0 = Relay with disable facility | |||
D.047 | Current outside temperature | (with Vaillant weather-compensated control) Actual value in °C | Not ad- justable | |||
D.050 | Offset min. speed | In rpm, adjustment range: 0 to 3000 | Nominal value set in factory | |||
D.051 | Offset max. speed | In rpm, adjustment range: -990 to 0 | Nominal value set in factory | |||
D.058 | Solar post-heating | 0 = Solar post-heating deactivated 3 = DHW activation target value minimum 60 °C, thermo- static mixing valve required between product and draw- off point | 0 = Solar post-heating deactivated | |||
D.060 | Number of safety therm. shut- downs | Number of shutdowns | Not ad- justable | |||
D.061 | No. of shut-downs in ign. flame controller | Number of unsuccessful ignitions in the last attempt | Not ad- justable | |||
D.064 | Avg. ignition time | In seconds | Not ad- justable | |||
D.065 | Max. ignition time | In seconds | Not ad- justable | |||
D.067 | Remaining anti-cycl. time for heat- ing | In minutes | Not ad- justable | |||
D.068 | Number of first start attempts | Number of unsuccessful ignitions | Not ad- justable | |||
D.069 | Number of second start attempts | Number of unsuccessful ignitions | Not ad- justable | |||
D.070 | 3-way valve operation | 0 = Normal operating mode 1 = Parallel operation (mid-position) 2 = Permanent heating position | 0 = Normal operating mode | |||
D.071 | Max. heating target flow temp. | 40 to 80 °C | 75 °C | |||
D.072 | Pump overrun after cylinder char- ging | Adjustable from 0–10 minutes in increments of 1 minute | 2 mins | |||
D.073 | Offset setting for comfort mode | Adjustable from-15Kto5K | 0 | |||
D.074 | Anti-legionella funct. with integ- rated cyl. | 0 = Off 1 = On | 1 = On | |||
D.075 | Max. cylinder charging time | 20–90 min | 45 mins | |||
D.076 | Device Specific Number | Device specific number = DSN 1 = VU 126/5-5 (H-GB) ecoTEC plus 612 3 = VU 156/5-5 (H-GB) ecoTEC plus 615 4 = VU 186/5-5 (H-GB) ecoTEC plus 618, VU 186/5-5 (P-GB) ecoTEC plus 618 9 = VU 246/5-5 (H-GB) ecoTEC plus 624 14 = VU 306/5-5 (H-GB) ecoTEC plus 630, VU 306/5-5 (P-GB) ecoTEC plus 630 20 = VU 386/5-5 (H-GB) ecoTEC plus 637 6 = VUW 196/5-5 (H-GB) ecoTEC plus 825 10 = VUW 246/5-5 (H-GB) ecoTEC plus 832, VUW 246/5-5 (P-GB) ecoTEC plus 832 62 = VUW 306/5-5 (H-GB) ecoTEC plus 835 17 = VUW 286/5-5 (H-GB) ecoTEC plus 838, VUI 286/5- 5 (H-GB) ecoTEC plus 938 | Not ad- justable | |||
D.077 | DHW partial load | Adjustable cylinder charging output in kW | ||||
D.078 | DHW max. flow temperature | Limit on cylinder charging temperature in °C 50 °C – 80 °C Note The chosen value must be at least 15 K or 15 °C above the target cylinder value. | 75 °C | |||
D.080 | Heating operating hours | In hours (h) | Not ad- justable | |||
D.081 | DHW operating hours | In hours (h) | Not ad- justable | |||
D.082 | Heating burner starts | Number of burner start-ups | Not ad- justable | |||
D.083 | DHW burner starts | Number of burner start-ups | Not ad- justable | |||
D.084 | Maintenance in | Adjustment range: 0 to 3000 hrs and "---" for deactivated | „---” | |||
D.088 | Min. DHW flow rate | Switch-on delay for domestic hot water draw-off detec- tion via impeller (only products with integrated domestic hot water generation) 0 = 1.5 l/min and no delay, 1 = 3.7 l/min and 2 sec. delay | 1.5 l/min and no delay | |||
D.090 | eBUS controller | Status of digital control Recognised, not recognised | Not ad- justable | |||
D.091 | DCF77 Status with connected external proble with DCF77 receiver | 0 = no reception 1 = reception 2 = synchronised 3 = valid | Not ad- justable | |||
D.092 | actoSTOR communication status | actoSTOR module detection 0 = Not connected 1 = Connection fault: No communication via PeBus, actoSTOR module was previously detected 2 = Connection active | Not ad- justable | |||
D.093 | Adjust Device Specific Number | Device Specific Number (DSN) Adjustment range: 0 to 99 | ||||
D.094 | Clear fault history | Delete fault list 0 = No 1 = Yes | ||||
D.095 | Software version: PeBUS parti- cipant | PCB (BMU) Display (AI) actoSTOR (APC) HBI/VR34 | Not ad- justable | |||
D.096 | Reset to factory settings? | Reset all adjustable parameters to factory setting 0 = No 1 = Yes | ||||
D.097 | Activation of the second diagnostic level | Password:17 | Password:17 | |||
D.098 | Coding resistor | Display xx.yy xx = Coding resistor 1 in cable harness for output range: 8 = VU 126/5-5 (H-GB) ecoTEC plus 612; VU 156/5-5 (H-GB) ecoTEC plus 615; VU 186/5-5 (H-GB) ecoTEC plus 618, VU 186/5-5 (P-GB) ecoTEC plus 618; VUW 196/5-5 (H-GB) ecoTEC plus 825 9 = VU 246/5-5 (H-GB) ecoTEC plus 624; VUW 246/5-5 (H-GB) ecoTEC plus 832; VUW 246/5-5 (P-GB) ecoTEC plus 832 10 = VU 306/5-5 (H-GB) ecoTEC plus 630; VU 306/5-5 (P-GB) ecoTEC plus 630; VUW 306/5-5 (H-GB) ecoTEC plus 835 11 = VU 386/5-5 (H-GB) ecoTEC plus 637; VUW 286/5- 5 (H-GB) ecoTEC plus 838; VUI 286/5-5 (H-GB) ecoTEC plus 938 yy = Coding resistor 2 on PCB for gas group: 02 = P gas 03 = H gas 07 = L gas | Not ad- justable |
Vaillant D Codes New
Disclaimer: Information on this website is provided for informational purpose therefore we cannot accept liability for subsequent problems. All repair tasks should be carried out by qualified trades people. We may also receive commission payments when you are taken to external websites and complete purchases from third party sellers, once you leave our site, we cannot be held liable for your purchases.