| No | Symbol | Description and Explanation | Models Applicable to |
|---|---|---|---|
| 0 | Current Flow temperature of heated water leaving the boiler heat exchanger | All | |
| 1 | Flame: Permanently on: Correct burner operation; Burner on | New Ecotec | |
| 2 | Display of the current burner modulation rate (bar graph display) The bar graph will go up and down depending on the power level the boiler is firing at. |
New Ecotec | |
| 3 | Flame: Permanently on: Correct burner operation; Burner on | Older Ecotec | |
| 4 | Flame with cross: Boiler is at lock out and will display fault code | Older Ecotec | |
| 5 | Display of the current filling pressure of the heating system (bar graph display) The filling pressure must be in the mid range between the two dotted lines. – Permanently on: The filling pressure is within the permitted range. – Flashing: The filling pressure is outside of the permitted range |
||
| 6 | Heating mode active – Permanently on: Heat demand, heating mode |
||
| 6.1 | Heating mode active – Flashing: Burner on in heating mode |
||
| 7 | Hot water generation active – Permanently on: In draw-off mode before burner is on – Flashing: Burner on in draw-off mode |
||
| 7.1 | Hot water generation active – Flashing: Burner on in draw-off mode |
||
| 8 | Hot water generation active For VUI (Storage Combination) / VUW (Combination) boilers: – Permanently on, burner is on: In draw-off mode |
||
| 8.1 | Hot water generation active – Flashing: Burner on in draw-off mode |
||
| 9 | Hot water generation active On VU (System / OpenVent) boilers: – Permanently on: time slot activated for hot water generation |
||
| 9.1 | Hot water generation active – Flashing: Domestic hot water cylinder is being heated, burner on |
||
| 10 | Maintenance / Service required In the "Live monitor", you can read further information about the reason for the service |
||
| 11 | Summer mode active Heating mode is switched off Decrease the heating flow temp until it says off. Increase the flow temp to original value to turn heating back on. |
||
| 12 | Boiler anti-cycling time is active This function is used to prevent frequent on/off operations, and therefore contributes to prolonging the life of your boiler. The symbol also appears if the boiler is in a waiting period. |
||
| 13 | Internal pump is running | ||
| 14 | Gas valve is activated | ||
| 15 | F.XX Fault in the boiler Appears instead of the basic display. A plain text display explains the displayed fault code. Example: F.10 Flow NTC short circuit. |