Smarter Heating & Hot Water

Vaillant F85 Fault Code

Flow and return NTCs incorrectly fitted

Back to Vaillant Fault Codes

Gas Safe: Gas work, flue work, and PCB replacement on a gas boiler must be carried out by a Gas Safe registered engineer. Homeowners can check obvious items such as heating pressure, condensate overflow, and whether a control is unplugged — then call an engineer.

Always confirm the part number against the boiler GC number and the installation manual before ordering.

Overview

F.85 is more specific than F.84: both sensors are on the same pipe, or on the wrong pipes entirely.

Vaillant meaning: Flow and return NTCs incorrectly fitted

Possible causes

Possible solutions

  1. Refit: one NTC on flow, one on return, as labelled in the manual.
  2. Reset and run a demand. Flow should rise first.

Possible parts needed

Vaillant NTC SensorVaillant Flow / Return NTC 193592
Vaillant PCB X20 Connector
Vaillant PCB X20 connector (typical NTC loom)