Smarter Heating & Hot Water

Vaillant F78 Fault Code

Interruption to DHW outlet sensor at external controller

Back to Vaillant Fault Codes

Gas Safe: Gas work, flue work, and PCB replacement on a gas boiler must be carried out by a Gas Safe registered engineer. Homeowners can check obvious items such as heating pressure, condensate overflow, and whether a control is unplugged — then call an engineer.

Always confirm the part number against the boiler GC number and the installation manual before ordering.

Overview

F.78 means a UK link box (or similar external control interface) is connected, but the domestic hot-water NTC is not bridged or not fitted. The PCB is waiting for a DHW outlet sensor that is not there.

Vaillant meaning: Interruption to DHW outlet sensor at external controller

Possible causes

Possible solutions

  1. If no external DHW sensor is required, fit the manufacturer’s bridge / link on the DHW NTC terminals as shown in the link-box instructions.
  2. If a DHW outlet NTC is required, fit and plug it in, then check the lead.
  3. Remove or rewire the link box if it should not be on this boiler.

Possible parts needed