F.23 Meaning

This fault according to Vaillant Instructions and Servicing manual is a Heating Flow NTC Thermistor Fault or Heating Flow NTC short circuit

Cause of F23

Solutions to repair this fault

Check the Flow and return NTC sensors. Check the wiring using a continuity tester and resistance tester if necessary. Replace NTC, harness or PCB as necessary dependent on checks.

Make sure there are no blockages in the pipework.  If there is debris in the system, flushing may be required. Then individual components may require cleaning or replacing dependent on damage caused by debris.  You may need to activate the pump purge program (see P Codes). Also check the domestic heat exchanger is free of debris, cleaning the filter as necessary.

Vaillant Flow / Return NTC 193592Vaillant NTC Sensor

Models applicable to:

Ecotec Pro, Ecotec Plus, Ecotec Exclusive.