Overview
F.20 is overheat protection. The boiler has gone above the safety limit (or the limiter circuit has been fooled by a bad earth, NTC, or ignition tracking). Do not keep resetting it without finding why it overheated.
Vaillant meaning: Safety switch-off: temperature limiter
Possible causes
- Poor earth between harness and boiler (including ignition earth)
- Flow or return NTC loose, drifted, or swapped so the PCB under-reads temperature
- Tracking / black discharge on the ignition lead, plug, or electrode
- True overheat from no circulation (pump, air, sludge, closed valves) — often seen with F.23 / F.24 / F.76
Possible solutions
- Do not keep firing into lockout. Check system pressure and that TRVs / zone valves are not isolating all flow.
- Prove earth continuity to the heat exchanger, burner door, and electrode earth tag.
- Inspect the ignition lead and electrode for tracking. Replace if carbon-tracked.
- Measure flow and return NTCs (about 12 kΩ at 20 °C) and confirm they are on the correct pipes.
- If circulation is poor, diagnose pump, air, and heat-exchanger blockage before changing electronics.
Possible parts needed
- Flow/return NTC 193592 or 0020068120
- Ignition electrode (e.g. 090709 or 0020133816 by range)
- Ignition lead / plug
- Pump / debris in the hydroblock
- PCB (last)