Smarter Heating & Hot Water

Intergas Fault Codes

Main display codes for Intergas boilers.

Back to fault codes

Main Display CodeFaultPossible SolutionResources
10,11,12,13,14Sensor fault S1
Flow switch does not disconnect
• Check wiring for break
• Replace S1
• Check flow switch
20,21,22,23,24Sensor fault S2• Check wiring for break
• Replace S2
0Sensor fault after self check• Replace S1 and/or S2
1Temperature too high• Air in installation
• Pump not running
• Unsufficient flow in installation, radiators closed, pump setting too low
• Flow switch sticking
2S1 and S2 interchanged• Check cable loom
• Replace S1 or S2
4No flame signal• Gas tap closed
• No or incorrect ignition gap
• Gas supply pressure too low of failling
• Gas valve or ignition unit not powered
5Poor flame signal• Condensate drain blocked
• Check adjustment of gas valve
6Flame detection fault• Replace ignition cable + spark plug cap
• Replace ignition unit
• Replace boiler controller
8Incorrect fan speed• Fan catching on casing
• Wiring between fan and casing
• Check wiring for poor wire contact
• Replace fan*
29,30Gas valve relay faulty• Replace boiler controller

Gas work stays with a Gas Safe registered engineer. Some codes only apply to a named range — check the model column.