Fault codesMeaningPossible causeModel
F.00Fault: Flow temperature sensorNTC plug not plugged in or has come loose, multiple plug on the PCB not plugged in correctly, interruption in cable harness, NTC sensor defectiveEnergy
F.01Fault: Return temperature sensorNTC plug not plugged in or has come loose, multiple plug on the PCB not plugged in correctly, interruption in cable harness, NTC sensor defectiveEnergy
F.10Short circuit: Flow temperature sensorNTC sensor defective, short circuit inthe cable harness, cable/casingEnergy
F.11Short circuit: Return temperature sensorNTC sensor defective, short circuit in the cable harness, cable/casingEnergy
F.12 and F.91Short circuit: Cylinder temperature sensorNTC sensor defective, short circuit in the cable harness, cable/casingEnergy
F.13Short circuit: Domestic hot water cylinder temperature sensorNTC sensor defective, short circuit in the cable harness, cable/casingEnergy
F.20Safety switch-oft. Overheating temperature reachedIncorrect earth connection between cable harness and product, flow or return NTC defective (loose connection), black discharge viaignition cable, ignition plug or ignition electrodeEnergy
F.22Safety switch-oft. Low water pressure in the boilerNo or insufficient water in the product, water pressure sensor defective, cable lo the pump or to the water pressure sensor loose/not connected/defectiveEnergy
F.23Safety switch-oft. Temperature difference too great (NTC1/NTC2)Pump blocked, insufficient pump output, air in product, flow and return NTC sensoni connected the wrong way roundEnergy
F.24Safety switch-oft. Temperature rise too fastPump blocked, insufficient pump output, air in product, system pressure too low, non-return valve blocked/incorrectly installedEnergy
F.25Safety switch-off. Flue gas temperature too highBreakin plug connection for optional flue gas safety temperature limiter (STB), break in cable harnessEnergy
F.27Safety switch-off. Fault in flame detectionMoisture on the electronics, electronics (flame monitor) defective. gas solenoid valve leakingEnergy
F.28Fault: Ignition unsuccessful when starting upGas meter defeclive or gas pressure monitor has triggered, air in gas, gas flow pressure too low, thermal isolator device (TAE) has triggered, incorrect gas restrictor,incorrect spare gas valve, fault on the gas valve, multiple plug on PCB incorrectly plugged in, break in cable harness,ignition system (ig-nition transformer, ignition cable, ignition plug, ignition electrode) defective, ionisation current interrupted (cable, electrode), incorrect earthing of product. electronics defectiveEnergy
F.29Fault: Flame lossGas supply temporarily stopped, flue gas recirculation, incorrect earthing of product, ignition transformer has spark fallureEnergy
F.32Fan frost protection function active: Fan speed outside the tolerance valuesPlug on fan not correctly plugged in, multiple plug on PCB not correCUy plugged in, breakin cable harness, fan blocked, Hall sensor defective, electronlcs defectiveEnergy
F.33Fan frost protection function active: Air pressure switch faultPressure monitor has not switched or has switched at a fan speed value that is too high (insufficient air supply) | Pressure monitor plug not correctly plugged in, pressure monitor defective, hose removed from between the pressure monitor and silencer, air/flue pipe blockedEnergy
FA9eBUS fault: Voltage too lowShort circuit on eBUS. eBUS overload or two power supplies with different polarities on the eBUSEnergy
F.61Fault: Gas valve control systemShort circuit/short to earth in cable harness for the gas valve, gas valve defective (colls shorted to earth), electronics defectiveEnergy
F.82Fault: Gas valve switch-off controlDelayed switch-off of gas valve, delayed extinguishing of flame signal,gas valve leaking, electronics defectiveEnergy
F.83Fault: EEPROMElectronics defectiveEnergy
F.64Fault: Electronics/sensor/analogue-to-digital converterFlow or return NTC short circuited, electronics defectiveEnergy
F.85Fault: Electronics temperature too highElectronics overheating due to external influences, electronics defectiveEnergy
F.67Value sent back by ASIC is incorrect (flame slgnal)Implausible flame signal, electronics defectiveEnergy
F.88Fault: Unstable flame (analogue input)Air in gas, gas flow pressure too low, incorrect air ratio, incorrect gas restricter, ionisation flow interruption (cable, electrode)Energy
F.70Invalid product code (DSN)Display and PCB replaced alsame time and Device Specific Number not reset, wrong or missing output range coding resistanceEnergy
F.71Fault: Flow/return temperature sensorFlow temperature sensor signaling constant value: Flow temperature sensor incorrectly positioned on supply pipe, flow temperature sensor defectiveEnergy
F.72Fault: Deviation in the water pressure sensor/return temperature sensorFlow/return NTC temperature difference too great -> flow and/or return temperature sensor defectiveEnergy
F.73Fault: Water pressure sensor not connected or has short-circuitedInterruption/short circuit of water pressure sensor, lntarrupaon/short circuit to GND in supply line to water pressure sensor or water pressure sensor defectiveEnergy
F.74Fault: Electrical problemin the water pressure sensorLine to water pressure sensor has a short circuit to 5 V/24 V or internal fault in the water pressure sensorEnergy
F.75Fault: Pressure sensorPressure switch defectiveEnergy
F.78The safety cut-out in the primary heat exchanger is defectiveSafety cut-out feedback does not match the gas valve feedbackEnergy
F.77Fault: Condensate or smokeNo response, flue non-return flap defectiveEnergy
F.78Interruption to DHW outlet sensor at external controllerUK ink box is connected, but hot water NTC not bridgedEnergy
F.83Fault: Burner temperature sensorBurner temperature sensor is defective| When the burner starts, the temperature change registered at the flow or retum temperature sensor is non-existent or too small: insufficient water in the product, the flow or retum temperature sensor is not in the correct position on the pipeEnergy
F.84Fault: Flow/return temperature sensorValues not consistent, difference < -6 K | Flow and return temperature sensors signalling implausible values: Flow and return temperature sensors have been inverted, flow and return temperature sensors have not been correctly InstalledEnergy
F.85Fault: Temperature sensorThe flow and/or return temperature sensors have been installed on the same pipe/incorrect pipe | Temperature sensor not connected or is connected incorrectlyEnergy
F.88Fault: Underfloor heating contactUnderfloor heating contact open, sensor disconnected or defectiveEnergy
F.87Fault: ElectrodesElectrodes not connected or they are connected incorrectly, short circuit in the cable harnessEnergy
F.88Fault: Gas valveGas valve not connected or it is connected incorrecUy, short circuit in the cable harnessEnergy
F.89Fault: PumpPump not connected or it is connected incorrectly, incorrect pump connected, short circuit in the cable harnessEnergy
ConnectionNo communication between the PCB and the user interfaceElectronics defectiveEnergy
CodesDescriptionModel
ErrUser interface faultUltracom sxi`
ErrUser interface faultUltracom cxi
ErrUser interface faultUltracom 35 store
ErrUser interface faultBetacom a
F00No faultXtrafast 96/120E1
F00No faultXtrafast 96/120
F00Flow heating temperature sensor faultUltracom sxi
F00Flow heating temperature sensor faultUltracom cxi
F00Flow heating temperature sensor faultUltracom 35 store
F00Flow heating temperature sensor faultBetacom a
F01Return heating temperature sensor faultUltracom sxi
F01Return heating temperature sensor faultUltracom cxi
F01Return heating temperature sensor faultUltracom 35 store
F01Return heating temperature sensor faultBetacom a
F02Air flow faultXtrafast 96/120E1
F02Air flow faultXtrafast 96/120
F02Hot water temperature sensor faultUltracom 35 store
F03Storage tank temperature sensor faultUltracom 35 store
F04Ignition fault - flame detectionXtrafast 96/120E1
F04Ignition fault - flame detectionXtrafast 96/120
F05OverheatingXtrafast 96/120E1
F05OverheatingXtrafast 96/120
F06Central heating thermistor/wiring faultXtrafast 96/120E1
F06Central heating thermistor/wiring faultXtrafast 96/120
F07Domestic hot water thermistor/wiring faultXtrafast 96/120E1
F07Domestic hot water thermistor/wiring faultXtrafast 96/120
F08Storage vessel thermistor/wiring faultXtrafast 96/120E1
F08Storage vessel thermistor/wiring faultXtrafast 96/120
F09System pressure sensor faultXtrafast 96/120E1
F09System pressure sensor faultXtrafast 96/120
F10Fan faultXtrafast 96/120E1
F10Fan faultXtrafast 96/120
F10Flow heating temperature sensor faultUltracom sxi
F10Flow heating temperature sensor faultUltracom cxi
F10Flow heating temperature sensor faultUltracom 35 store
F10Flow heating temperature sensor faultBetacom a
F11Poor circulationXtrafast 96/120E1
F11Poor circulationXtrafast 96/120
F11Return heating temperature sensor faultUltracom sxi
F11Return heating temperature sensor faultUltracom cxi
F11Return heating temperature sensor faultUltracom 35 store
F11Return heating temperature sensor faultBetacom a
F12User interface faultXtrafast 96/120E1
F12User interface faultXtrafast 96/120
F12Hot water temperature sensor faultUltracom 35 store
F13Main pcb faultXtrafast 96/120E1
F13Main pcb faultXtrafast 96/120
F13Storage tank temperature sensor faultUltracom 35 store
F14Central heating flow temperature > 97 degreesXtrafast 96/120E1
F14Central heating flow temperature > 97 degreesXtrafast 96/120
F15Gas mechanism faultXtrafast 96/120E1
F15Gas mechanism faultXtrafast 96/120
F20Communication faultXtrafast 96/120E1
F20Communication faultXtrafast 96/120
F20Overheating faultUltracom sxi
F20Overheating faultUltracom cxi
F20Overheating faultUltracom 35 store
F20Overheating faultBetacom a
F22Low water pressureUltracom sxi
F22Low water pressureUltracom cxi
F22Low water pressureUltracom 35 store
F22Low water pressureBetacom a
F23Water circulation faultUltracom sxi
F23Water circulation faultUltracom cxi
F23Water circulation faultUltracom 35 store
F23Water circulation faultBetacom a
F24Water circulation faultUltracom sxi
F24Water circulation faultUltracom cxi
F24Water circulation faultUltracom 35 store
F24Water circulation faultBetacom a
F26Fault in gas valveUltracom sxi
F26Fault in gas valveUltracom cxi
F26Fault in gas valveUltracom 35 store
F26Fault in gas valveBetacom a
F27Flame detection faultUltracom sxi
F27Flame detection faultUltracom cxi
F27Flame detection faultUltracom 35 store
F27Flame detection faultBetacom a
F28Ignition faultUltracom sxi
F28Ignition faultUltracom cxi
F28Ignition faultUltracom 35 store
F28Ignition faultBetacom a
F29Loss of flame during operationUltracom sxi
F29Loss of flame during operationUltracom cxi
F29Loss of flame during operationUltracom 35 store
F29Loss of flame during operationBetacom a
F32Incorrect air pressureUltracom sxi
F32Incorrect air pressureUltracom cxi
F32Incorrect air pressureUltracom 35 store
F32Incorrect air pressureBetacom a
F49EBUS voltage faultUltracom sxi
F49EBUS voltage faultUltracom cxi
F49EBUS voltage faultUltracom 35 store
F49EBUS voltage faultBetacom a
F61Fault in the main boardUltracom sxi
F61Fault in the main boardUltracom cxi
F61Fault in the main boardUltracom 35 store
F61Fault in the main boardBetacom a
F62Fault in the main boardUltracom sxi
F62Fault in the main boardUltracom cxi
F62Fault in the main boardUltracom 35 store
F62Fault in the main boardBetacom a
F63Fault in the main boardUltracom sxi
F63Fault in the main boardUltracom cxi
F63Fault in the main boardUltracom 35 store
F63Fault in the main boardBetacom a
F64Fault in the main boardUltracom sxi
F64Fault in the main boardUltracom cxi
F64Fault in the main boardUltracom 35 store
F64Fault in the main boardBetacom a
F65Fault in the main boardUltracom sxi
F65Fault in the main boardUltracom cxi
F65Fault in the main boardUltracom 35 store
F65Fault in the main boardBetacom a
F67Fault in the main boardUltracom sxi
F67Fault in the main boardUltracom cxi
F67Fault in the main boardUltracom 35 store
F67Fault in the main boardBetacom a
F68Fluctuation of flame signalUltracom sxi
F68Fluctuation of flame signalUltracom cxi
F68Fluctuation of flame signalUltracom 35 store
F68Fluctuation of flame signalBetacom a
F70User interface incompatible with the main boardUltracom sxi
F70User interface incompatible with the main boardUltracom cxi
F70User interface incompatible with the main boardUltracom 35 store
F70User interface incompatible with the main boardBetacom a
F71Flow heating temperature sensor faultUltracom sxi
F71Flow heating temperature sensor faultUltracom cxi
F71Flow heating temperature sensor faultUltracom 35 store
F71Flow heating temperature sensor faultBetacom a
F72Permanent temperature difference between flow and return heating sensorsUltracom sxi
F72Permanent temperature difference between flow and return heating sensorsUltracom cxi
F72Permanent temperature difference between flow and return heating sensorsUltracom 35 store
F72Permanent temperature difference between flow and return heating sensorsBetacom a
F73Heating circuit pressure sensor faultUltracom sxi
F73Heating circuit pressure sensor faultUltracom cxi
F73Heating circuit pressure sensor faultUltracom 35 store
F73Heating circuit pressure sensor faultBetacom a
F74Heating circuit pressure sensor faultUltracom sxi
F74Heating circuit pressure sensor faultUltracom cxi
F74Heating circuit pressure sensor faultUltracom 35 store
F74Heating circuit pressure sensor faultBetacom a
F76Thermal fuse faultUltracom sxi
F76Thermal fuse faultUltracom cxi
F76Thermal fuse faultUltracom 35 store
F76Thermal fuse faultBetacom a
F77Fault in gas valve motorUltracom sxi
F77Fault in gas valve motorUltracom cxi
F77Fault in gas valve motorUltracom 35 store
F77Fault in gas valve motorBetacom a
F79Storage tank temperature sensor faultUltracom 35 store
F81Overheating of hot water circuitUltracom 35 store
F83No water in the installationUltracom sxi
F83No water in the installationUltracom cxi
F83No water in the installationUltracom 35 store
F83No water in the installationBetacom a
F84Permanent temperature difference between flow and return heating sensorsUltracom sxi
F84Permanent temperature difference between flow and return heating sensorsUltracom cxi
F84Permanent temperature difference between flow and return heating sensorsUltracom 35 store
F84Permanent temperature difference between flow and return heating sensorsBetacom a
F85Flow and Return heating sensor faultUltracom sxi
F85Flow and Return heating sensor faultUltracom cxi
F85Flow and Return heating sensor faultUltracom 35 store
F85Flow and Return heating sensor faultBetacom a
F86Underfloor heating contact faultUltracom sxi
F86Underfloor heating contact faultUltracom cxi
F86Underfloor heating contact faultUltracom 35 store
F86Underfloor heating contact faultBetacom a
CodesDescriptionModel
F1Ignition faultXtramax HE
F1Ignition faultUltrapower sxi
F1Ignition faultUltracom sxi
F1Ignition faultUltracom hxi
F1Ignition faultUltracom cx
F1Ignition faultUltracom cxi
F1Ignition faultsxi
F1Ignition faultSI
F1Ignition faulthxi
F1Ignition faultflexicom sx
F1Ignition faultflexicom hx
F1Ignition faultflexicom cx
F1Ignition faultcxi
F1Ignition faultCI Plus
F1Ignition faultCI
F10Central return flow thermistorXtramax HE
F10Central return flow thermistorUltrapower sxi
F10Central return flow thermistorUltracom sxi
F10Central return flow thermistorUltracom hxi
F10Central return flow thermistorUltracom cx
F10Central return flow thermistorUltracom cxi
F10Central return flow thermistorsxi
F10Central return flow thermistorSI
F10Central return flow thermistorhxi
F10Central return flow thermistorflexicom sx
F10Central return flow thermistorflexicom hx
F10Central return flow thermistorflexicom cx
F10Central return flow thermistorcxi
F10Central return flow thermistorCI Plus
F10Central return flow thermistorCI
F11Main board connection faultXtramax HE
F11Main board connection faultUltrapower sxi
F11Main board connection faultUltracom sxi
F11Main board connection faultUltracom hxi
F11Main board connection faultUltracom cx
F11Main board connection faultUltracom cxi
F11Main board connection faultsxi
F11Main board connection faultSI
F11Main board connection faulthxi
F11Flow and or return thermistor faultflexicom sx
F11Flow and or return thermistor faultflexicom hx
F11Flow and or return thermistor faultflexicom cx
F11Main board connection faultcxi
F11Main board connection faultCI Plus
F11Main board connection faultCI
F12User interface connection faultXtramax HE
F12Connection fault between main pcb and display pcbsxi
F12Connection fault between main pcb and display pcbSI
F12Connection fault between main pcb and display pcbhxi
F12Connection fault between main pcb and display pcbcxi
F12Connection fault between main pcb and display pcbCI Plus
F12Connection fault between main pcb and display pcbCI
F13PCB memory or sensing faultXtramax HE
F13PCB memory or sensing faultUltrapower sxi
F13PCB memory or sensing faultUltracom sxi
F13PCB memory or sensing faultUltracom hxi
F13PCB memory or sensing faultUltracom cx
F13PCB memory or sensing faultUltracom cxi
F13Main pcb connection faultsxi
F13Main pcb connection faultSI
F13Main pcb connection faulthxi
F13PCB memory or sensing faultflexicom sx
F13PCB memory or sensing faultflexicom hx
F13PCB memory or sensing faultflexicom cx
F13Main pcb connection faultcxi
F13Main pcb connection faultCI Plus
F13Main pcb connection faultCI
F14Gas valve control defectiveXtramax HE
F14Gas valve control defectiveUltrapower sxi
F14Gas valve control defectiveUltracom sxi
F14Gas valve control defectiveUltracom hxi
F14Gas valve control defectiveUltracom cx
F14Gas valve control defectiveUltracom cxi
F14Central heating flow temperature > 95 degreessxi
F14Central heating flow temperature > 95 degreesSI
F14Central heating flow temperature > 95 degreeshxi
F14Gas valve control defectiveflexicom sx
F14Gas valve control defectiveflexicom hx
F14Gas valve control defectiveflexicom cx
F14Central heating flow temperature > 95 degreescxi
F14Central heating flow temperature > 95 degreesCI Plus
F14Central heating flow temperature > 95 degreesCI
F15E-bus voltage failureUltrapower sxi
F15E-bus voltage failureUltracom sxi
F15E-bus voltage failureUltracom hxi
F15E-bus voltage failureUltracom cx
F15E-bus voltage failureUltracom cxi
F15Gas valve stepper motor faultsxi
F15Gas valve stepper motor faultSI
F15E-bus voltage failureflexicom sx
F15E-bus voltage failureflexicom hx
F15E-bus voltage failureflexicom cx
F15Gas valve stepper motor faultcxi
F15Gas valve stepper motor faultCI Plus
F15Gas valve stepper motor faultCI
F16Flame detection faultXtramax HE
F16Flame detection faultsxi
F16Flame detection faultSI
F16Flame detection faulthxi
F16Flame detection faultcxi
F16Flame detection faultCI Plus
F16Flame detection faultCI
F17Power supply is less than 170vXtramax HE
F17Power supply is less than 170vsxi
F17Power supply is less than 170vSI
F17Power supply is less than 170vhxi
F17Power supply is less than 170vcxi
F17Power supply is less than 170vCI Plus
F17Power supply is less than 170vCI
F18User interface faultXtramax HE
F18User interface faultsxi
F18User interface faultSI
F18User interface faulthxi
F18User interface faultcxi
F18User interface faultCI Plus
F18User interface faultCI
F19Central heating thermistor unpluggedXtramax HE
F19Central heating thermistor unpluggedsxi
F19Central heating thermistor unpluggedSI
F19Central heating thermistor unpluggedhxi
F19Central heating thermistor unpluggedcxi
F19Central heating thermistor unpluggedCI Plus
F19Central heating thermistor unpluggedCI
F2FanXtramax HE
F2Fansxi
F2Fan/APSSI
F2Fanhxi
F2Fancxi
F2Fan/APSCI Plus
F2Fan/APSCI
F20Software incompatibilityXtramax HE
F20Software incompatibilitysxi
F20Software incompatibilitySI
F20Software incompatibilityhxi
F20Software incompatibilitycxi
F20Software incompatibilityCI Plus
F20Software incompatibilityCI
F22Low water pressure or ignition temperature rise too slowUltrapower sxi
F22Low water pressure or ignition temperature rise too slowUltracom sxi
F22Low water pressure or ignition temperature rise too slowUltracom hxi
F22Low water pressure or ignition temperature rise too slowUltracom cx
F22Low water pressure or ignition temperature rise too slowUltracom cxi
F22Low water pressure or ignition temperature rise too slowflexicom sx
F22Low water pressure or ignition temperature rise too slowflexicom hx
F22Low water pressure or ignition temperature rise too slowflexicom cx
F23Water circulation faultXtramax HE
F24Cental heating return temperature > 90 degreesXtramax HE
F24Cental heating return temperature > 90 degreessxi
F24Cental heating return temperature > 90 degreeshxi
F24Central heating return temperature > 90 degreesflexicom cx
F24Central heating return temperature > 90 degreescxi
F25Maximum temperature rise slopeXtramax HE
F25Circulation faultUltrapower sxi
F25Circulation faultUltracom sxi
F25Circulation faultUltracom hxi
F25Circulation faultUltracom cx
F25Circulation faultUltracom cxi
F25Poor circulationsxi
F25Poor circulationhxi
F25Circulation faultflexicom sx
F25Circulation faultflexicom hx
F25Circulation faultflexicom cx
F25Poor circulationcxi
F26Maximum delta temperatureXtramax HE
F26Poor circulationsxi
F26Poor circulationhxi
F26Poor circulationcxi
F3FanXtramax HE
F3Fan unable to reach ignition speedUltrapower sxi
F3Fan unable to reach ignition speedUltracom sxi
F3Fan unable to reach ignition speedUltracom hxi
F3Fan unable to reach ignition speedUltracom cx
F3Fan unable to reach ignition speedUltracom cxi
F3Fan unable to reach ignition speedsxi
F3Fan unable to reach ignition speedhxi
F3Fan unable to reach ignition speedflexicom sx
F3Fan unable to reach ignition speedflexicom hx
F3Fan unable to reach ignition speedflexicom cx
F3Fan unable to reach ignition speedcxi
F3Air faultCI Plus
F4Ignition faultXtramax HE
F4Ignition faultUltrapower sxi
F4Ignition faultUltracom sxi
F4Ignition faultUltracom hxi
F4Ignition faultUltracom cx
F4Ignition faultUltracom cxi
F4Ignition faultsxi
F4Ignition faultSI
F4Ignition faulthxi
F4Ignition faultflexicom sx
F4Ignition faultflexicom hx
F4Ignition faultflexicom cx
F4Ignition faultcxi
F4Ignition faultCI Plus
F4Ignition faultCI
F43Generic errorUltrapower sxi
F43Generic errorUltracom sxi
F43Generic errorUltracom hxi
F43Generic errorUltracom cx
F43Generic errorUltracom cxi
F43Generic errorflexicom sx
F43Generic errorflexicom hx
F43Generic errorflexicom cx
F5Overheat FaultXtramax HE
F5Overheat FaultUltrapower sxi
F5Overheat FaultUltracom sxi
F5Overheat FaultUltracom hxi
F5Overheat FaultUltracom cx
F5Overheat FaultUltracom cxi
F5Overheat Faultsxi
F5Overheat FaultSI
F5Overheat Faulthxi
F5Overheat Faultflexicom sx
F5Overheat Faultflexicom hx
F5Overheat Faultflexicom cx
F5Overheat Faultcxi
F5Overheat FaultCI Plus
F5Overheat FaultCI
F6Central heating flow thermistorXtramax HE
F6Central heating flow thermistorUltrapower sxi
F6Central heating flow thermistorUltracom sxi
F6Central heating flow thermistorUltracom hxi
F6Central heating flow thermistorUltracom cx
F6Central heating flow thermistorUltracom cxi
F6Central heating flow thermistorsxi
F6Central heating flow thermistorSI
F6Central heating flow thermistorhxi
F6Central heating flow thermistorflexicom sx
F6Central heating flow thermistorflexicom hx
F6Central heating flow thermistorflexicom cx
F6Central heating flow thermistorcxi
F6Central heating flow thermistorCI Plus
F6Central heating flow thermistorCI
F7Domestic hot water thermistorXtramax HE
F7Domestic hot water thermistorsxi
F7Domestic hot water thermistorSI
F7Domestic hot water thermistorhxi
F7Domestic hot water thermistorflexicom sx
F7Domestic hot water thermistorflexicom cx
F7Domestic hot water thermistorcxi
F7Domestic hot water thermistorCI Plus
F7Domestic hot water thermistorCI
F70Software incompatibleUltrapower sxi
F70Software incompatibleUltracom sxi
F70Software incompatibleUltracom hxi
F70Software incompatibleUltracom cx
F70Software incompatibleUltracom cxi
F70Software incompatibleflexicom sx
F70Software incompatibleflexicom hx
F70Software incompatibleflexicom cx
F73Unable to see pump activateUltrapower sxi
F73Unable to see pump activateUltracom sxi
F73Unable to see pump activateUltracom hxi
F73Unable to see pump activateUltracom cx
F73Unable to see pump activateUltracom cxi
F73Unable to see pump activateflexicom sx
F73Unable to see pump activateflexicom hx
F73Unable to see pump activateflexicom cx
F77Condensate pump error (optional)Ultrapower sxi
F77Condensate pump error (optional)Ultracom sxi
F77Condensate pump error (optional)Ultracom hxi
F77Condensate pump error (optional)Ultracom cx
F77Condensate pump error (optional)Ultracom cxi
F77Condensate pump error (optional)flexicom sx
F77Condensate pump error (optional)flexicom hx
F77Condensate pump error (optional)flexicom cx
F8Tank thermistorXtramax HE
F8Tank thermistor (N/A For this appliance)sxi
F8Tank thermistor (N/A For this appliance)SI
F8Tank thermistor (N/A For this appliance)hxi
F8Tank thermistor (N/A For this appliance)cxi
F8Tank thermistor (N/A For this appliance)CI Plus
F8Tank thermistor (N/A For this appliance)CI
F9Water pressure sensor fault (please contact GW technical department for further information)Xtramax HE
F9Water pressure sensor fault, blocked flow filter or pump faultUltrapower sxi
F9Water pressure sensor fault, blocked flow filter or pump faultUltracom sxi
F9Water pressure sensor fault, blocked flow filter or pump faultUltracom hxi
F9Water pressure sensor fault, blocked flow filter or pump faultUltracom cx
F9Water pressure sensor fault, blocked flow filter or pump faultUltracom cxi
F9Water pressure sensor fault (please contact GW technical department for further information)sxi
F9Water pressure sensor fault (please contact GW technical department for further information)SI
F9Earlier models only (please contact GW technical department for further information)hxi
F9Low water pressure Sensorflexicom sx
F9Low water pressure Sensorflexicom hx
F9Water pressure sensor fault, blocked flow filter or pump faultflexicom cx
F9Water pressure sensor fault (please contact GW technical department for further informationcxi
F9Water pressure sensor fault (please contact GW technical department for further informationCI Plus
F9Water pressure sensor fault (please contact GW technical department for further informationCI
No display or Erloose connection X51Ultrapower sxi
No display or Erloose connection X51Ultracom sxi
No display or Erloose connection X51Ultracom hxi
No display or Erloose connection X51Ultracom cx
No display or Erloose connection X51Ultracom cxi

Gas work stays with a Gas Safe registered engineer. Some codes only apply to a named range — check the model column.