Smarter Heating & Hot Water

Ariston Fault Codes

Display codes for Clas, E-Combi, E-System and related Ariston ranges.

Back to Advice

The first digit is the circuit: 1xx heating, 2xx DHW / solar, 3xx internal PCB, 4xx external PCB / room sensors, 5xx ignition, 6xx air / flue, 7xx multi-zone. A P in the code (1P1, 5P3) is a warning, not a lockout. Some numbers only apply to a named range — check the model column before you order parts.

Gas work stays with a Gas Safe registered engineer. This table is the display meaning, not a substitute for the Ariston handbook.

Code Section Possible cause Boiler model
101Central heatingOverheatAll boilers
102Central heatingPressure sensor errorE-Combi Evo, E-System Evo, Clas HE Evo (combi and system)
103Central heatingInsufficient circulationAll boilers
104Central heatingInsufficient circulationAll boilers
105Central heatingInsufficient circulationAll boilers
106Central heatingInsufficient circulationAll boilers
107Central heatingInsufficient circulationAll boilers
108Central heatingInsufficient water (request filling)All combi boilers
109Central heatingSystem pressure greater than 3 barClas Net One / Clas One Combi, Clas System One
110Central heatingCentral heating flow temperature probe open / short circuitAll boilers
112Central heatingCentral heating return temperature probe open / short circuitAll boilers
114Central heatingExternal sensor circuit open / short circuitAll boilers
116Central heatingFloor thermostat contact openAll combi and system boilers
118Central heatingHeating delivery probe problemAll boilers
1P1Central heatingInsufficient circulation indicationAll boilers
1P2Central heatingInsufficient circulation indicationAll boilers
1P3Central heatingInsufficient circulation indicationAll boilers
1P4Central heatingInsufficient circulation indicationClas Net One Combi, Clas One Combi, Clas System One
202DHWBottom storage temperature probe open / short circuitClas HE Evo, Clas HE Evo System, E-Combi Evo, E-System Evo
204DHWSolar collector temperature probe open / short circuitClas HE Evo, Clas HE Evo System, E-Combi Evo, E-System Evo
205DHWDomestic hot water in probe open circuitClas HE Evo, Clas HE Evo System, E-Combi Evo, E-System Evo
207DHWSolar collector overheatingClas HE Evo, Clas HE Evo System, E-Combi Evo, E-System Evo
208DHWCollector frost protection temperatureClas HE Evo, Clas HE Evo System, E-Combi Evo, E-System Evo
301Internal PCBEEPROM errorAll boilers
302Internal PCBCommunication errorAll boilers
303Internal PCBMain PCB errorAll boilers
304Internal PCBToo many resets (more than 5 in 15 minutes)All boilers
305Internal PCBMain PCB errorAll boilers
306Internal PCBMain PCB errorAll boilers
307Internal PCBMain PCB errorAll boilers
3P9Internal PCBSchedule serviceE-Combi One, E-System One, Clas Net One Combi, Clas One Combi, Clas System One
407External PCBRoom sensor circuit open / short circuitClas HE Evo, Clas HE Evo System, E-Combi Evo, E-System Evo
411External PCBRoom sensor circuit open or short circuit zone 1Clas Net One, Clas One, E-Combi, E-System
412External PCBRoom sensor circuit open or short circuit zone 2Clas Net One, Clas One, E-Combi, E-System
414External PCBRoom sensor circuit open or short circuit zone 3Clas Net One, Clas One, E-Combi, E-System
501Ignition and detectionNo flame detectedAll boilers
502Ignition and detectionFlame detected with gas valve closedAll boilers
504Ignition and detectionFlame liftAll boilers
5P1Ignition and detection1st ignition failedAll boilers
5P2Ignition and detection2nd ignition failedAll boilers
5P3Ignition and detectionFlame cut-offAll boilers
604Air inlet / flueInsufficient fan speedClas HE R, E-Combi Evo, E-System Evo, Clas HE Evo Combi, Clas HE Evo System
610Air inlet / flueThermofuse openAll boilers
612Air inlet / flueFan speed has incorrect measurementClas HE Evo Combi, Clas HE Evo System, E-Combi Evo, E-System Evo, Clas Net One Combi, Clas One Combi, Clas System One
701Multi-zoneZone 2 outgoing sensor defectiveE-Combi Evo, E-System Evo, Clas HE Evo Combi, Clas HE Evo System
702Multi-zoneZone 2 return sensor defectiveE-Combi Evo, E-System Evo, Clas HE Evo Combi, Clas HE Evo System
703Multi-zoneZone 3 outgoing sensor defectiveE-Combi Evo, E-System Evo, Clas HE Evo Combi, Clas HE Evo System
704Multi-zoneZone 3 return sensor defectiveE-Combi Evo, E-System Evo, Clas HE Evo Combi, Clas HE Evo System
705Multi-zoneHydraulic separation sensor defectiveE-Combi Evo, E-System Evo, Clas HE Evo Combi, Clas HE Evo System
706Multi-zoneZone 2 overheatingE-Combi Evo, E-System Evo, Clas HE Evo Combi, Clas HE Evo System
707Multi-zoneZone 3 overheatingE-Combi Evo, E-System Evo, Clas HE Evo Combi, Clas HE Evo System
701Multi-zoneSend sensor defective (zone 1)Clas Net One, Clas One, E-Combi, E-System
702Multi-zoneSend sensor defective (zone 2)Clas Net One, Clas One, E-Combi, E-System
703Multi-zoneSend sensor defective (zone 3)Clas Net One, Clas One, E-Combi, E-System
711Multi-zoneReturn sensor defective (zone 1)Clas Net One, Clas One, E-Combi, E-System
712Multi-zoneReturn sensor defective (zone 2)Clas Net One, Clas One, E-Combi, E-System
713Multi-zoneReturn sensor defective (zone 3)Clas Net One, Clas One, E-Combi, E-System
722Multi-zoneOverheating in zone 2Clas Net One, Clas One, E-Combi, E-System
723Multi-zoneOverheating in zone 3Clas Net One, Clas One, E-Combi, E-System
750Multi-zoneAll heating zones lockedClas Net One, Clas One, E-Combi, E-System

Codes 701–703 mean different sensors on Evo / Clas HE Evo versus Clas One / Net One. Use the model column, not the number alone.

Related: Vaillant fault codes · boiler pressure (108 / 109).