Radiator Correction Factor Tool

Calculate radiator output at different delta T values for heat pump systems and conventional heating.

Emitter Output at Delta T

Emitter Output (BTU / KW) 1000
Select Delta T (°C / K)
Emitter Output (at Delta T)
1000.00
BTU / KW
This calculator will tell you what output you will end up with if you reduce the delta T to the selected from the dropdown.

Required Radiator Output at Delta 50°C

Heatloss (BTU / KW required) 1000
Select Delta T (°C / K)
Output of Emitter at Delta 50°C needed
1000.00
BTU / KW
This calculator is used to work out which standard radiators at 50 degrees delta to meet the needs of heat pumps.

Delta T Conversion Factor Table

Delta T (°C / K) Conversion Factor
50.05
100.123
150.209
17.500.257
200.304
250.406
300.515
350.629
400.748
450.872
501.000
551.132
601.267
651.406
701.694
Important: These calculations are based on radiator performance curves. Always consult manufacturer data sheets for specific radiator models and verify calculations with a qualified heating engineer.