How to – Vaillant Arotherm Plus Setting the Flow Rates

Flow rates can be viewed by using the WWZ Al MB2 or MEH 97/uniTOWER display.

Access by pressing the top 2 buttons at the same time (possibly twice as usually the first press will light the display up)

Use the + button to scroll down the menu to installer level,
– press top right-hand button to select The access code is 17, use + button to adjust,
– press top right-hand button to select Use the + button to scroll down to Test menu,
– press top right-hand button to select Use the + button to scroll down to Sensor/Actuator test,
– press top right-hand button to select Press + button 10 times to view Building circuit: Flow rate

If the flow rate needs to be adjusted, then this can be accessed by following the below:

Access by pressing the top 2 buttons at the same time (possibly twice as usually the first press will light the display up)

Use the + button to scroll down the menu to installer level,
– press top right-hand button to select The access code is 17, use + button to adjust,
– press top right-hand button to select Use the + button to scroll down to Configuration,
– press top right-hand button to select Press the + button 7 times to Max. remaining feed head,
– press top right-hand button to adjust

Note. You may need to adjust max. remaining feed head and recheck the flow rate in test menu – sensor/actuator test – building circuit flow rate. Max remaining feed head parameter adjusts the pump in both heating and domestic hot water modes.

Disclaimer: Information on this website is provided for informational purpose therefore we cannot accept liability for subsequent problems. All repair tasks should be carried out by qualified trades people. We may also receive commission payments when you are taken to external websites and complete purchases from third party sellers, once you leave our site, we cannot be held liable for your purchases.