Smarter Heating & Hot Water

Vaillant F71 Fault Code

Flow NTC fault (constant value)

Fault codes / Vaillant

Gas Safe: Gas work, flue work, and PCB replacement on a gas boiler must be carried out by a Gas Safe registered engineer. Homeowners can check obvious items such as heating pressure, condensate overflow, and whether a control is unplugged — then call an engineer.

Always confirm the part number against the boiler GC number and the installation manual before ordering.

Overview

F.71 means the flow NTC is not changing when it should — stuck reading, poorly clipped to the pipe, or insulated from the pipe. Different from F.00 (open) and F.10 (short).

Vaillant meaning: Flow NTC fault (constant value)

Possible causes

Possible solutions

  1. Look at the flow pipe: the NTC must be tight on bare pipe or fully in the pocket.
  2. Run a heat demand and watch D.40 (flow temperature) if you have diagnostic access. A dead-flat reading while the flow pipe is getting hot is F.71.
  3. Replace the NTC if mounting is correct and the reading still does not move.

Possible parts needed

Part numbers must be confirmed by a Gas Safe professional against the boiler GC number before ordering or fitting. Use 193592 or 0020068120 only when that number matches the boiler — they are not interchangeable on every appliance.

Shopping links are affiliate links — see Affiliate activity disclosure.

Vaillant NTC SensorVaillant Flow / Return NTC 193592
Vaillant PCB X20 Connector
Vaillant PCB X20 connector (typical NTC loom)