- Version
- Download 0
- File Size 504 KB
- File Count 1
- Create Date January 11, 2020
- Last Updated January 11, 2020
Baxi Bermuda SL3 Installation and Servicing Instructions
Baxi Bermuda SL3 Installation and Servicing Instructions
GC No
|
Model
|
Fuel Type
|
|
---|---|---|---|
37-077-60 | Baxi Bermuda SL3 | NG |
Natural Gas
Baxi Bermuda SL3
G.C.No 37 077 60
For use with the following boilers:
Bermuda 45/4 M G.C.No 44 077 71
Bermuda 45/4 E G.C.No 44 077 73
Bermuda 57/4 M G.C.No 44 077 72
Bermuda 57/4 E G.C.No 44 077 74
Renewal
Baxi Bermuda SL3 Renewal G.C.No 37 075 02A
For use with the following boilers:
B.S. Codes of Practice
Bermuda 401 G.C.No 44 077 49
Bermuda 552 G.C.No 44 077 50
Bermuda 45/3 M G.C.No 44 077 61
Bermuda 45/3 E G.C.No 44 077 60
Bermuda 57/3 M G.C.No 44 077 63
Bermuda 57/3 E G.C.No 44 077 62
Bermuda 45/4 M G.C.No 44 077 71
Bermuda 45/4 E G.C.No 44 077 73
Bermuda 57/4 M G.C.No 44 077 72
Bermuda 57/4 E G.C.No 44 077 74
This unit is the gas fire section of the Bermuda SL3 central heating boiler and gas fire. The heat input is 5.70kW (19,450 Btu/h) and the fire is available for use with Gas Type G20 (Natural Gas) at 20mbar or Gas Type G31 (Propane). The fire is controlled by a knob positioned on the right hand side of the case. Ignition is by piezo spark to the pilot (Fig 13). For details of Propane appliances see back page.
The control knob has six positions giving a choice of four output rates.
STANDARD B.S. 6891 B.S. 5546
B.S. 5871
B.S. 5440: Part 1 B.S. 5440: Part 2 B.S. 6798
B.S. 5449: Part 1
INTRODUCTION
SCOPE
Gas Installation.
Installation of hot water supplies for domestic purposes.
Installation of gas fires, convectors and fire/back boilers.
Flues
Air Supply
Installation of gas fired hot water boilers.
Forced circulation hot water systems.
POSITION POSITION POSITION 1 POSITION 2 POSITION 3 POSITION 4
- THE FIRE IS OFF.
- IGNITION/PILOT.
- THE FIRE IS ON LOW.
- THE FIRE IS ON MEDIUM.
- THE FIRE IS ON MEDIUM/HIGH. - THE FIRE IS ON HIGH.
Propane Gas
Baxi Bermuda SL3 Propane
G.C.No 37 077 70
For use with the following boiler: Bermuda 553 Propane
G.C.No 44 077 75